NEII is the premier trade association representing the global leaders in the building transportation industry. Its members install, maintain, and/or manufacture elevators, escalators, moving walks, and other building transportation products. NEII‘s membership includes the six major international companies – Fujitec America, Inc., KONE, Inc., Mitsubishi Electric US, Inc., Otis Elevator Company, Schindler Elevator Corporation, TK Elevator and several other companies across the country. Collectively, the NEII members represent approximately eighty percent of the total hours worked within the elevator and escalator industry, employ more than 25,000 people in the U.S. and indirectly support hundreds of thousands of American jobs in affiliate industries. 

For more information about NEII, please visit www.neii.org


RECEIVE IMPORTANT INDUSTRY UPDATES

JOIN THE NEII INSIDER NEWSLETTER

NEII Position on the Adoption of ASME A17.1/CSA B44-16

The most effective way of ensuring the safety of the riding public as well as elevator personnel is by the adoption of the latest version of the ASME A17.1/CSA B44 Safety Code for Elevators and Escalators. This state-of-the-art code is widely used throughout North America and is updated regularly. The code represents the optimum in safety as it is developed and refined by hundreds of experienced experts representing all aspects of the elevator industry. Such expertise is drawn from enforcing authorities, mechanical and electrical engineering and design experts, inspectors, consultants, labor authorities, building and facility owners, and installation and maintenance specialists.

The code development process consists of a thorough consensus-building protocol which invites examination of proposed code language and the opportunity to comment on and suggest modifications to such language. The process also includes the opportunity for a thorough public review of any proposed language. In view of the thoroughness of the process, all issues are examined in-depth, and pitfalls and shortcomings are fully addressed before publication of the code.

 
Particular attention is given to requirements for acceptance and periodic inspection as well as ongoing maintenance. Such requirements are regularly updated to ensure the highest levels of safety.
Adoption of the most recent version of the ASME A17.1/CSA B44 code without modification in all jurisdictions ensures a uniform high level of safety throughout North America. 

 

ASME A17.1-2016/CSA B44-16 is the latest version of the code, published November 30, 2016 with an effective date of May 30, 2017. Some of the important enhancements in this edition of the code are as follows:


  • Added requirements for hoistway access switch location, Phase I recall operation with closed hoistway doors, escalator braking distance monitor, and requirements for elevators not in automatic operation.
  • Updated seismic requirements for consistency with the ICC International Building Code, the National Building Code of Canada, and ASCE 7.
  • Updated overhead clearance requirements to compensate for removal of refuge space in earlier edition. Updated requirements for Rack & Pinion and Special Purpose Personnel Elevators. Moved Wind Turbine Elevator requirements to new A17.8 document.
  • Reduced hoistway door to car door clearances on Private Residence elevators and added car door deflection and strength criteria. Updated and clarified several requirements for existing elevators and alterations.

NEII is committed to public and elevator personnel safety and is ready to support the authorities having jurisdiction in understanding the latest version of the code and assisting in the process of adoption. To this end NEII provides information and training on the code and related issues, using webinars and podcasts in addition to meetings with interested parties.


Approved:
The NEII Central Code Committee is responsible for maintaining this position paper. This position paper shall be in effect for three (3) years from the date of approval by the NEII Central Code Committee.


NEII Central Code Committee: July 19, 2017


About NEII

NEII is the premier trade association representing the global leaders in the building transportation industry. Its members install, maintain, and/or manufacture elevators, escalators, moving walks, and other building transportation products. NEII‘s membership includes the six major international companies – Fujitec America, Inc., KONE, Inc., Mitsubishi Electric US, Inc., Otis Elevator Company, Schindler Elevator Corporation, TK Elevator Company and several other companies across the country. Collectively, the NEII members represent approximately eighty percent of the total hours worked within the elevator and escalator industry, employ more than 25,000 people in the U.S. and indirectly support hundreds of thousands of American jobs in affiliate industries. 

For more information about NEII, please visit www.neii.org

NEII Position on Fire Service Access Elevators in the 2012 IBC


This position paper is issued by the National Elevator Industry, Inc. (NEII) in response to concerns about a conflict between the requirements for Fire Service Access Elevators (FSAE) in the 2021 IBC and ASME A17.1/CSA B44. In addition, it addresses a clarification provided by the 2015 IBC.


The 2012 IBC added a new requirement addressing elevator Phase I emergency recall operation. This requirement was deleted in the 2015 IBC.


“3007.2 Phase I Emergency recall operation. Actuation of any building fire alarm-initiating device shall initiate Phase I emergency recall operation on all fire service access elevators in accordance with the requirements in ASME A17.1/CSA B44. All other elevators shall remain in normal service unless Phase I emergency recall operation is manually initiated by a separate, required three-position, key-operated “Fire Recall” switch or automatically initiated by the associated elevator lobby, hoistway or elevator machine room smoke detectors. In addition, if the building also contains occupant evacuation elevators in accordance with Section 3008, an independent, three-position, key-operated “Fire Recall” switch conforming to the applicable requirements in ASME A17.1/CSA B44 shall be provided at the designated level for each fire service access elevator.”

 

The conflict is created by the first sentence. It requires initiation of Phase I emergency recall operation in accordance with ASME A17.1/CSA B44 but also states that it should be upon activation of any building fire alarm initiating device.


The ASME A17.1/CSA B44 Safety Code for Elevators and Escalators referenced by the IBC requires fire alarm initiating devices installed in conformance to NFPA 72 to be located at each elevator lobby, associated elevator machine rooms and spaces, and in the elevator hoistway to initiate FEO Phase1 emergency recall operation (section 2.27.3.2.1).


The NFPA 72 Fire Alarm and Signaling Code, section 21.3.3 requires only the elevator lobby, hoistway and machine room detectors to be used to recall elevators for fire fighter service unless otherwise required by the AHJ. Initiation of Phase I elevator recall upon activation of any fire alarm initiating device in the building is not permitted.


Elevators recalled unnecessarily by FAIDs outside of the elevator lobby, hoistways and machine rooms are not available to persons with disabilities who require elevators to egress the building. This will require resources from first responders to locate and evacuate those persons. The use of these resources could be better deployed addressing the fire/emergency.


Unnecessary recall of the elevators may also create confusion and cause delays for the firefighters. The confusion and delays would occur if all elevators are recalled because the firefighters will not know which ones are safe to use. If only the affected elevators are recalled the firefighters can capture a non- recalled elevator immediately for their use.


Elevators that are recalled on Phase I Emergency recall operation by “any fire alarm-initiating device” will require either elevator personnel or emergency personnel to reset Phase I Emergency recall operation so that the recalled elevator(s) can return to automatic operation. By code this cannot be done by building personnel. The result will be unnecessary removal of elevators from automatic operation and significant delays in returning these elevators to automatic operation.


Requiring compliance with this policy in existing buildings that currently comply with ASME A17.1/CSA B44 creates significant burdens in the areas of permitting, inspections, equipment, and costs.


Another concern expressed with the 2012 IBC was the requirements in 3007.7.5 for the Fire Service access elevator symbol are not clear. There were two issues. The first was that it was not clear how the three inch minimum dimension was applied. The second was due to the fact that the code book is not printed in color and there was some confusion as to whether the symbol had to be black and white only. Both of these issues were clarified in the 2015 IBC. The three inch dimension applies to the rectangular field around the fire hat. The symbol is allowed to be any combination of light and dark colors to provide contrast.


NEII is committed to public and elevator personnel safety and is ready to support the authorities having jurisdiction in understanding the latest version of the code and assisting in the process of adoption. To this end NEII provides information and training on the code and related issues, using webinars and podcasts in addition to meetings with interested parties.


Approved:

The NEII Central Code Committee is responsible for maintaining this position paper. This position paper shall be in effect for three (3) years from the date of approval by the NEII Central Code Committee.


NEII Central Code Committee: February 19. 2016